Page 28 RS-500/600 Series Doors Part No 4801-5154 Rev 01-2015
17 Installation of Condensation Management System and Ducts
Install the Condensation Management System at the top of the Freezer Door approximately in the center of the door
as shown below. Install the 5/7” Duct Adaptor in the intake side of the Condensation Management System.
Carefully run the duct work to the two couplings on the left and right track of the door. Fasten each end of the duct
with hose Clamps.
17.1 Connecting the Electrical Power
1. Connect the RollSeal SC-325 and SC-650 Controller to Door Control Box.
2. Refer to the RollSeal SC-325 and SC-650 Controller Manual (4801-5156) for instructions on wiring.
3. Refer to the RollSeal SC-325 and SC-650 Controller Manual (4801-5156) for initial setup.
4. Connect the two control wires from the Condensation Management System to the
SC-325 and SC-650 Controller.
NOTE: For all Freezer
applications, the
SC-325 and SC-
650 Controller
“P4” program
setting must be set
to option “3”.